ICNR 2026 · Poster P-113

Preserving Clinically Relevant Gait Features in Wearable-Sensor Pose Estimation for Parkinson’s Disease

Kai Yang1, Haoyuan Sun1, Hiroyuki Hamada1, Ken Kikuchi1, Atsushi Yamashita1, Diego Torricelli2, and Qi An1,*

1The University of Tokyo  ·  2Centre for Automation and Robotics (CAR), Spanish National Research Council

Ground truth (GT) and reconstructions with pose-only (P) and clinical-aware (C) fine-tuning, using six IMUs or the head-free five-IMU set. Qualitative example from virtual IMUs, original playback speed.

Take-home message

Main result

C − P (absolute log-ratio error)Six IMUsFive IMUs
Joint velocity−0.025−0.037
Sagittal leg swing−0.027−0.022

Negative values mean lower error with clinical-aware tuning. All four 95% confidence intervals exclude zero. Virtual IMUs from 781 walks of 23 people with Parkinson’s disease; subject-wise cross-validation.

Cite

K. Yang, H. Sun, H. Hamada, K. Kikuchi, A. Yamashita, D. Torricelli, and Q. An, “Preserving Clinically Relevant Gait Features in Wearable-Sensor Pose Estimation for Parkinson’s Disease,” International Conference on NeuroRehabilitation (ICNR 2026), Seoul, Poster P-113.